2025 Caterpillar Diesel Generator Sets 35 3516E (50 Hz) 3500 kVA

Information

2025 Caterpillar Diesel Generator Sets 35 3516E (50 Hz) 3500 kVA

3000 - 3500 kVA Generator Set

The 3516E diesel generator sets have been developed to meet your standby and mission critical applications and match your power standards. Producing reliable power (3000 - 3500 kVA at 50 Hz), each generator set has been designed to meet ISO 8528-5 transient response requirements, accept 100 % rated load in one step and accept >50% block road recovering within G2 limits. The generator is certified Tier 2 Equivalent, US EPA Stationary Emergency / Low NOx (1/2 TA Luft).

Features may include:

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Photos

Highlights

  • Exeter, Rhode Island
  • 2025
  • Caterpillar
  • Diesel Generator Sets 35 3516E (50 Hz) 3500 kVA
  • Model: 3516E
  • Genset (maximum/minimum): 50706 lb/50706 lb
  • Available
  • Maximum/Minimum: 104 in/104 in
  • Maximum/Minimum: 131.6 in/131.6 in

Specifications

  • 2025
  • Caterpillar
  • Diesel Generator Sets 35
  • 3516E (50 Hz) 3500 kVA
  • General
  • Model: 3516E
  • V-16
  • 4-Stroke Diesel
  • Water-Cooled
  • 6.69 in
  • 8.46 in
  • 4765 in³
  • ATAAC
  • Tier 2 Equivalent
  • 14.7:1
  • Electronic Unit Injection
  • Type: Adem™5
  • Standby Rating: 3500 kVA | Prime Power Rating: 3000 kVA | Maximum Rating: 3500 kVA | Minimum Rating: 2725 kVA
  • Voltage: 380 to 11000 Volts | Frequency: 50 Hz
  • 1800 rpm
  • Maximum/Minimum: 335.1 in/335.1 in
  • Maximum/Minimum: 104 in/104 in
  • Maximum/Minimum: 131.6 in/131.6 in
  • Genset (maximum/minimum): 50706 lb/50706 lb
  • Duty Cycle: Standby, Mission Critical