Job-Site Equipment Corp.

  • 405 Nooseneck Hill Rd
  • Exeter, RI 02822
  • Call Us: (401) 785-9800
  • https://www.jobsiteequipment.com/
Print This Page

2022 Caterpillar Generator Set Control Panels EMCP 4.3 Control Panel

Information

2022 Caterpillar Generator Set Control Panels EMCP 4.3 Control Panel

The EMCP 4 Control Panel provides all of the controls and system indicators in one easy to access interface.

Features may include:

EMCP 4 CONTROLS
  • The EMCP 4 includes the following controls:
  • Auto / Start / Stop Control
  • Speed and Voltage Adjust
  • Engine Cycle Crank
  • Programmable Cycle Timer
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm/event descriptions
  • Remote start / stop
  • Engine Cooldown Timer
  • Local and remote emergency stop
Digital indicators
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • ekW, kVA, kVAR, kW-hr, %kW, PF
  • Battery voltage
  • Oil Temperature
  • Multiple Language Support
  • Crank attempt and successful start counter
  • Run hours
  • Enhanced engine monitoring (with electronic engines)
Warning / shutdown indicators
  • The EMCP 4 has common LED indicators of the following warning and shutdown conditions
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Low engine oil pressure (alarm)
  • High engine oil temp (alarm and shutdown)
  • High coolant temp (alarm and shutdown)
  • Low coolant temp (alarm)
  • Low coolant level (alarm)
  • Control switch not in auto (alarm)
  • Low, high, and weak battery voltage
Programmable protective relaying
  • Generator phase sequence
  • Over/Under voltage (27/59)
  • Over/Under Frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Reverse Power (kW)(32)
Communications
  • Six digital inputs
  • Emergency stop pushbutton
  • Six relay outputs (Form A)
  • Two relay outputs (Form C)
  • Two digital outputs
  • One Analog Input
  • customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
Compatibility
  • The EMCP 4 is compatible with:
  • Remote CAN annunciator
  • Remote serial annunciator
  • Local Annunciator
  • Remote Monitoring Software
  • Digital I/O module
  • RTD module
  • Thermocouple module
Display
  • A 33 x 132 pixel, 3.8 inch, graphical display denotes text alarm/event descriptions, set points, engine and generator monitoring and is visible in all lighting conditions
Generator monitoring
  • Voltage (L-L, L-N)
  • Current (Phase)
  • Average Volt, Amp, Frequency
  • kW, kVAr, kVA (Average, Phase, %)
  • Power Factor (Average, Phase)
  • kW-hr, kVAr-hr (total)

Photos

Highlights

  • Exeter, Rhode Island
  • 2022
  • Caterpillar
  • Generator Set Control Panels EMCP 4.3 Control Panel
  • Available

Specifications

  • 2022
  • Caterpillar
  • Generator Set Control Panels
  • EMCP 4.3 Control Panel
  • General